What is OH elevator?
In the elevator system, the OH (Overhead) part , also known as the space above the elevator shaft, is an extremely important factor that customers need to pay attention to when considering elevator installation. The height of the space above the elevator will depend on the type of elevator and its speed, and understanding the factors that affect OH will help customers make better elevator installation decisions.
First, the type of elevator will shape the OH. For example, a high-speed elevator may require a larger OH space to ensure safety and operational performance. Conversely, a low-speed elevator may require less OH space.
Second, the structure of the building also affects OH. Some buildings may have height constraints, which reduces the flexibility in designing OH for elevators.
Finally, technical factors such as suspension systems and support structures also need to be considered. Advanced designs and technologies can help reduce OH space while still ensuring elevator performance and safety.
Elevator OH height
The OH (Overhead) height of the elevator is an important factor that cannot be ignored during the installation and operation of the elevator. For a normal house, the floor height is usually between 3000mm and 3300mm. However, to ensure safety and optimal performance of the elevator, experts often recommend that the OH height should be maintained at 3800mm to 4200mm or more.
In new construction, designing and building the right OH height for the elevator is often easier, as you can calculate and adjust the necessary factors in advance. However, for renovation projects or townhouse projects, ensuring the right OH height can be more difficult due to space and structural constraints.
In this situation, flexibility and creativity in applying special elevator products and customized solutions are very important. Using modern and flexible solutions will help to optimize space and costs, while ensuring that the elevator operates in the safest and most efficient way, in accordance with the specific requirements of each construction project.
Understanding the requirements and factors influencing OH height and finding flexible and efficient solutions is important to ensure that the systemthang máyintegrated into the project in the most precise and convenient way.
Why is there a common standard for elevator OH?
Setting the standard for OH (Overhead) height in the elevator system is an indispensable part to ensure the safety and performance of the equipment. OH plays an important role because this is where the main components such as the traction machine, electrical cabinet, UPS rescue system and other safety equipment are installed.
Ensuring OH meets standards will bring many benefits, including:
Ensure safety
Ensuring the safety of elevator systems is a top priority in design and operation. The OH (Overhead) height of the elevator plays an important role in ensuring the safety of passengers and equipment, especially when the elevator operates at the highest floor.
When the elevator reaches the top floor, the OH height must ensure that there is a large enough clearance to avoid collision or conflict with the accompanying equipment and accessories, such as the elevator cabin and safety system. This helps to limit the risk of accidents in case the elevator operates unstablely or suddenly overspeeds.
A height of approximately 3000mm is generally considered to ensure adequate space for equipment above the cabin roof. However, the determination of a specific OH height must comply with specific safety standards and technical regulations, appropriate to the type of elevator and the specific installation environment.
Equipment installation space
In the process of designing and installing elevators, determining the installation space for equipment is an important factor. In particular, at the two ends of the elevator's travel, there must always be a travel limit system to ensure the safety of the elevator's movement.
However, if the OH height of the elevator does not meet the standard size, this may affect the performance and accuracy of the travel limit system. When there is not enough space, the sensors and travel limit devices will not work effectively, leading to the risk of unwanted incidents during elevator operation.
Therefore, ensuring the standard OH height is very important to ensure the safety and performance of the elevator system. Professionals need to pay attention to determining and complying with the installation space requirements to ensure the stable and safe operation of the elevator.
SEE MORE PRODUCTS:
Space for maintenance installation:
During the maintenance, repair and installation of equipment in the elevator system, having enough space is very important. Usually, technicians will have to climb to the roof of the cabin or enter the machine room to carry out these operations. Therefore, increasing the height of OH (the distance from the ceiling of the building to the roof of the cabin) will bring convenience to the technician's access and operations.
With enough space, technicians can easily access and perform maintenance and repair of equipment without difficulty. This helps increase efficiency and accuracy in the maintenance process of the elevator system. Moreover, having enough space also helps technicians work more safely and effectively, thereby ensuring the stability and sustainability of elevator operations.
During the maintenance, repair and installation of equipment in the elevator system, having enough space is very important. Usually, technicians will have to climb to the roof of the cabin or enter the machine room to carry out these operations. Therefore, increasing the height of OH (the distance from the ceiling of the building to the roof of the cabin) will bring convenience to the technician's access and operations.
With enough space, technicians can easily access and perform maintenance and repair of equipment without difficulty. This helps increase efficiency and accuracy in the maintenance process of the elevator system. Moreover, having enough space also helps technicians work more safely and effectively, thereby ensuring stability and sustainability for the operation of the system.thang máy.
Factors affecting elevator OH
Factors affecting the OH height of the elevator are important conditions that need to be considered to ensure the safe and efficient operation of the system. Below are the factors that need to be noted:
Elevator travel speed : The travel speed of the elevator can affect the required OH height. When the elevator operates at high speed, the OH height requirement will also increase to ensure the safety of passengers and goods.
Elevator installation location : The choice of elevator installation location can affect the OH height. In some cases, elevator installation in old or completed houses may have difficulty increasing the OH height due to space constraints.
Elevator Brand : Each elevator brand has different designs and sizes, so the OH height requirements will also vary depending on the specific product. Choosing a reputable and experienced elevator brand will help ensure that the elevator system is properly designed and installed.
Low OH Buildings: In the case of low OH family buildings, choosing the right and optimal elevator design will be very important. Careful consideration is needed to ensure that the elevator is integrated into the space in a reasonable way while still ensuring performance and safety.
Considering and properly meeting the above factors will help ensure that the OH height of the elevator meets the correct safety and performance standards, while ensuring flexibility and space saving for the project.
Comparison of elevator OH between machine room-less elevator and machine room elevator
| Elevator with machine room | Machine room-less elevator | |
| Concept | The OH (Overhead) height of an elevator with a machine room is measured from the floor level of the top floor door to the highest point of the winch hanger on the roof of the machine room, including the machine room loft. This is the distance from the highest point of the elevator car to the ceiling of the machine room, including auxiliary structures such as the winch hanger and the machine room loft. The OH height determines the minimum height that the elevator machine room must have to ensure the safety and efficient operation of the elevator. | The OH (Overhead) height of a machine room-less elevator is measured from the floor level of the highest landing door to the highest point of the elevator's top hoist hook. This is the distance from the highest point of the elevator car to the ceiling of the landing, including hoist hangers and other structures on top of the elevator. The OH height is important to ensure free space above the elevator and enough space for the elevator car to move safely and efficiently. |
| Characteristic | In addition to the standard height, there must be additional space for the machine room above. | Only the top floor needs to be of standard height according to the specific type of ladder. |
| Height OH | The OH (Overhead Height) of an elevator with a machine room is calculated from the floor of the highest floor to the floor where the elevator traction machine is located. Normally, to ensure the safe and efficient operation of the elevator, this OH height should be 4200mm or more. At the same time, there must be a large enough space for the machine room, with a minimum height of 1,200mm or more. This helps to ensure that the traction machine equipment and other components have enough necessary space and comfort to carry out maintenance and repair activities later. In this way, not only the usable space is optimized, but also the convenience and performance of the elevator during operation and maintenance are ensured. | The OH (Overhead Height) of a machine room-less elevator is measured from the floor of the highest floor to the ceiling of the elevator shaft where the hoist hook is located. To ensure safe and efficient operation of the elevator, this OH height is usually recommended to be 4500mm or more. This size ensures that there is enough space for the elevator to move safely and conveniently. |